1.0 Purpose / 目的
To evaluate if the sample operated with the electronic components short-circuited or/and open can conform to the relevant safety requirements in UL1017.
评估样机电子组件在短路和/或断路非正常运行状况下是否符合UL1017安全标准.
2.0 Definition/概念:
None 无
3.0 Reference Documents/参考文献:
U.L.1017 CAN/CSA-C22.2 NO.243-01, dated 12-07-2001,Cl 5.10.2
4.0 Equipment/设备:
4.1 Frequency converter. (变频电源).
4.2 Stop watch(秒表)
4.3 UL finger (UL手指)
4.4 3 ampere non-time delay type fuse( 3A快速保险,插头型)
4.5 Withstanding voltage tester. (耐压测试仪)
4.6 White tissue paper(白纸).
4.7 Cheesecloth. (纱布)
4.8 Softwood board(软木板)
4.9 Digital multimeter(万用表)
5.0 General Instructions/说明:
5.1 Tests may be conducted at any ambient temperature within a range of 10-40℃ (50-100℉).
测试可在10~40℃(50~100℉)之内的环境温度下进行.
5.2 Unless otherwise noted, all tests are to be conducted with appliance connected to a 120VAC, 60Hz power source.
除非另外标注,否则所有样机都将连接在120V/60Hz电源下进行测试.
5.3 All equipment used must be calibrated on an annual basis. Calibration stickers with last calibration and calibration due date must be affixed to each instrument.
使用的所有设备都必须以一年为周期进行调校.载有最后调校日期和调校周期的调校粘纸必须粘固在每一个仪表上.
..............................
1.0 Purpose / 目的
To evaluate if the sample operated with the electronic components short-circuited or/and open can conform to the relevant safety requirements in UL1017.
评估样机电子组件在短路和/或断路非正常运行状况下是否符合UL1017安全标准.
2.0 Definition/概念:
None 无
3.0 Reference Documents/参考文献:
U.L.1017 CAN/CSA-C22.2 NO.243-01, dated 12-07-2001,Cl 5.10.2
4.0 Equipment/设备:
4.1 Frequency converter. (变频电源).
4.2 Stop watch(秒表)
4.3 UL finger (UL手指)
4.4 3 ampere non-time delay type fuse( 3A快速保险,插头型)
4.5 Withstanding voltage tester. (耐压测试仪)
4.6 White tissue paper(白纸).
4.7 Cheesecloth. (纱布)
4.8 Softwood board(软木板)
4.9 Digital multimeter(万用表)
5.0 General Instructions/说明:
5.1 Tests may be conducted at any ambient temperature within a range of 10-40℃ (50-100℉).
测试可在10~40℃(50~100℉)之内的环境温度下进行.
5.2 Unless otherwise noted, all tests are to be conducted with appliance connected to a 120VAC, 60Hz power source.
除非另外标注,否则所有样机都将连接在120V/60Hz电源下进行测试.
5.3 All equipment used must be calibrated on an annual basis. Calibration stickers with last calibration and calibration due date must be affixed to each instrument.
使用的所有设备都必须以一年为周期进行调校.载有最后调校日期和调校周期的调校粘纸必须粘固在每一个仪表上.
..............................